Georg Jordan offers its customers in the various industries secure, reliable and tested insulators for power distribution. The comprehensive range includes insulators types with specific mechanical and electrical properties for each application.

Georg Jordan insulators are mainly used in the power distribution automation, switch disconnectors and substations.

Georg Jordan offers for your technical or electrical requirements always an optimal solution. Please distinguish the products variants according to your features or application.

 

Low Voltage Insulators (LV)

Indoor use, from 0,5 up to 3,6 kV;
Cylindrical; with/without hexagonal profile;
With/without ribs;
Cast resin (Epoxy)
_________________________________________________________

Post Insulators Medium Voltage (MV)

Indoor use from 12 – 123 kV;
Cast resin (Epoxy)

Types:
RSGA – RSGE; 10 – 20 – 30; N / S
JO4 – J025 / 75 -145
RSG 45 – 30 – 60 – 72.5 – 110
_________________________________________________________

Bushings (LV – MV)

Indoor use 1 – 52 kV;
Cast resin (Epoxy)

Types:
SD – Screwable bushing 1 – 36 kV
KD – Clampable bushing 12 – 36 kV
RDGB – Bolt bushings 12 – 36 kV
RDIG – Draw lead bushings 12 – 52 kV
_________________________________________________________

 

Low Voltage Insulator (LV)

 

LV Standoff insulators / support insulators; 0, 5 – 3 kV

  • Design: cylindrical
  • With and without hexagonal Profile for easy and fast installation
  • Dimensions in height from 20 to 95 mm
  • Diameter of 20 to 60 mm

 

For example used for:

  • Disconnectors
  • Switchgear cabinets
  • Transformers
Standoff insulators for indoor use

LV Standoff insulators with ribs; 1 – 3, 6 kV

  • Design: cylindrical with ribs
  • Dimensions in height from 40 to 65 mm
  • Diameter of 62 to 100 mm

For example used for:

  • Disconnectors
  • Switchgear cabinets
  • Transformers
Standoff insulators for indoor use – RSG 1/3

Post Insulator Medium Voltage (MV)

MV Post insulators from 1 – 123 kV

Designs:

  • Cylindrical or conical with ribs
  • Dimensions in a level of 95 up to 1100 mm
  • Diameter of 52 up to 165mm

Custom products will be offered on request.

 

MV Post Insulators – cylindrical; 12 – 24 – 36 kV

Types:

A10 – CB30 / CC10 / N / S

JO4 – JO16 / 60 – 170

A 10 S – CB 30 N / S Isolator / Post Insulator 12 kV; 24 kV; 36 kV

MV Post Insulators – conical; 12 – 24 – 36 kV

Types:

  • RSGA 10 – RSGC 30 / N
  • JO6 – JO16 / 75 – 170
RSGA 10 N – RSGC 30 N Isolator / Post Insulator 12 kV; 24 kV; 36 kV

MV Post Insulators – cylindrical; 12 – 24 – 36 kV

Types:

  • RSGD 10 – RSGD 30 / N / S
  • RSGE 20
  • JO25 / 75 – 170
RSGD 10 N – RSGD 30 N / S RSGE 20 N Isolator / Post Insulator 12 kV; 24 kV; 36 kV

MV Post Insulators – conical; 52 – 72, 5 kV

Types:

  • RSGA 45 – RSG 72,5
  • JO6 – JO8 / 170 – 325
RSG 45 – RSG 72.5 Isolator / Post Insulator 52 kV and 72,5 kV

MV Post Insulators – conical; 123 kV

Types:

  • RSG 110 N / S
  • JO6 / 450 – 550
RSG 110 N / S Isolator / Post Insulator 123 kV

Bushings (Medium Voltage – Low Voltage)

 

LV Bushings for switchgears; 1 kV

Screwable bushings (SD); combination of base part and screw ring

  • Design: screwable
  • Screw ring; choice of sheet thickness from 2 – 8 mm
  • Inner diameter of 55 – 145 mm; choice regarding busbar design
  • Application: indoor use
  • Cast resin (Epoxy)

 

Types: SD 1 / 55 -145

SD – Screw type bushing, 1 kV

MV Bushings for switchgears; 12 – 24 – 36 kV

Optionally two mounting systems are available:

  1. Screwable bushing (SD); Combination of base part and screw ring
  2. Clampable bushing (KD); Combination of base part and and o-ring

 

  • Design: screwable or clampable
  • Screw ring; choice of sheet thickness from 2 – 12 mm
  • Inner diameter of 55 – 145 mm; choice regarding busbar design
  • Application: indoor use
  • Cast resin (Epoxy)

 

Types:

  • SD 10 – 30 / 55 – 145
  • KD 10 – 30 / 55 – 115
SD – Screw type bushing, 12 – 36 kV KD – Clamp bushing, 12 – 36 kV
  • KD 10 – 30 / 55 – 115; alternative metallised
KD 20-30 metallized flange

MV Wall bushings; 12 – 52 kV

Optionally two mounting systems are available:

  1. Bolt bushings (RDBG) of 12 – 24 – 36 – 52 kV; 200 – 1600 A;
  2. Draw lead bushings (RDIG) of 12 – 24 – 36 kV;

 

  • Design: with mounting flange
  • Dimensions  in length of 395 up to 1195 mm
  • Inner diameter of 95 up to 230 mm; choice regarding busbar design
  • Application: indoor use
  • Cast resin (Epoxy)
RDBG – Bolt bushings 12, 24, and 36 kV RDIG – Draw lead bushings 12, 24, 36, and 52 kV
RDIG 10 – 20 / 230 – Draw lead bushing 12 and 24 kV

Accessories for draw lead bushings

EPDM-busbar holder for

  • SD 1-30;
  • KD 10-30;
  • RDIG 10
  • Design: with mounting flange
  • Material EPDM
  • Standard or customized versions available on request
    (single, multiple, with / without radius; out of center, …)
Busbar holder EPDM

Aluminum busbar holder set for

  • RDIG 20-45;
  • SDE 10-30
Mounting set AL

Please contact our sales department sales@jordan.com.my for detailed information and drawings.